Circ-Oil Lube Consoles Lube Oil Purifiers Insulating Oil Purifiers Transformer Service Equipment Oil Regeneration Systems

Circ-Oil Lube Consoles

SESCO provides custom engineered circ-oil lube consoles for a wide variety of industry's most demanding bearing lubrication applications.

Read More >>

8-40 GPM VARIABLE SPEED OIL HEATING SKID

8-40 GPM VARIABLE SPEED OIL HEATING SKID






Variable Speed Oil Heating Skid
The SES/460 series is a skid mounted 96 kW low watt density electric oil heating system. The system includes a variable speed inlet pump designed to assist oil processors to be used as an inlet booster when poor suction conditions arise or a discharge booster / heater. This skid is complete with high temp / flow switch safety interlocks and includes a locally mounted variable speed drive, heater contacters and 100' power cable.  This unit is tested ready to ship.
 
 

PN: SES/460-96KW-480V-4X  EQUIPMENT OUTLINE

System Flow Circuit

Oil Piping Through Electric Heating System

Inlet and discharge isolation valves- (2")
Inlet and discharge quick connect cam connections (2")
Discharge flow sight
Local inlet and discharge pressure gauges
Local inlet and discharge heater assembly temperature gauges

Heating System

Electric

96 KW Low watt density electric heating system
50F Temperature rise / pass @ 30 GPM ( 50 GPM max flow rate)
11.5 watts / in
(3) 32 KW Heating banks - w/ individual panel switches
Nema 4 Digital temperature controller
Heater ON / OFF sequencing provided
Individual element high temperature shut down protection provided
Redundant oil flow switch interlocks provided 

Filtration 

Inlet Strainer

Coarse inlet strainer provided.

Control Package

Description

Control Package

PLC logic in the heater is used to provide unattended automatic fail safe operation.
Illuminated selector switches are provided for manual heater bank control and status indication.
Panel mounted digital temperature controller provided.
250A main circuit breaker provided
All packages are built to NEMA and IEC specifications
Main power disconnect switch / breaker
100% circuit breaker protected
Low flow and high temperature alarms lights provided.

Equipment Construction

 

 

 

Skid mounted with a recessed deck plate for drip collection.

Lifting cage provided with removable side walls and top.
Fork lift provisions provided.
 
Piping
 All oil piping is welded carbon steel w/ butt weld or socket fittings. Maintenance connections use bolted flanges or O-ring sealed unions. Threaded unions are not used. Threaded connections are kept to a minimum.  
Electrical Conduit

    A combination of ridged and liquid tight flexible conduit is used to provide a water tight easy maintenance wiring system.